Hi my new hybrid solar system does not find any voltage from the cells, before switching the cells on to the system, i can measure between 307 and 330 V form them, but when i switch them on the voltage drops to 2 V. can it be the connectors between the cells? It likely has been finding something while you're not watching it, stopping and starting as it thinks it's seeing sundown and a new day. To know for sure you must use a DC multimeter. It directs the voltage and current hailing from the solar panels setting off to the electric cell. Please check the voltage at battery terminals every 10 minutes. Connected everything while the controller was not yet mounted. A solar charge controller is a regulator for your solar battery that prevents it from overcharging. At Sunstore we are often asked about how the solar charge controller load output terminal should be used. +/- 1 V is acceptable. On my solar inverter the indicator always shows that by 9.00am every it is fully charged, but as soon as night falls we do not have enough to turn on even one light bulb. Inverter does not store any energy?! The system has been in our family for 4 years. It has only been in service for about 2 months. Is there anyone I can talk to who can help me trouble shoot the system. After implementing Solar solution I notice that whenever I on d breaker from the combiner the current raises to the acquired value but within a few seconds the current starts dropping until it reaches 0amps.will like to know if it's d charge controller faults or otherwise? Charge controller (MPPT 75/15) lights not turning on I recently chose to replace an older PWM controller with a Victron MPPT 75/15 charge controller, and yesterday I hooked them up to my fully charged battery bank (12.85 V before starting). When your batteries are low, the controller provides a full flow of current from your solar panels to replenish your battery banks. my inverter is not charging and writing " no sun" when the sun is shining and its very hot. This system is small, only 660 Watts. It trips instantly as I try to reset it. Preventing the battery from overcharging is important merely because the voltage generated by even a 12V solar panel is actually higher – between 16 and 20V. My mother put in a solar system (started in July, was fully up in December) and has yet to get any benefits from it. Once I get back to my cabin 4 weeks later, the batteries were fully charged and I could connect using the Bluetooth app. For Further Reading – MPPT _Pdf I have not gone further to not … Some of these can be fixed at home, and others can't. thax, Use a mult-metre and measure the voltage from the PV, battery and inverter. Therefore, as suggested by Bennett, discard the charge controller and just connect the panel directly to the battery. My inverter shuts off immediately l turn it on. Common Reasons an Xbox One Controller Won't Turn On Most of the problems preventing an Xbox One controller from turning on are related to the batteries or battery contacts, the charge and play kit, firmware problems, or internal hardware faults. Its job is to regulate the battery charging process to ensure the battery is charged correctly, or more importantly, not over-charged. Adhere another next to it and rewire. what do I have to do?? Many panels have blocking diodes built in but some do not. I have 2 180w panels connected in parallel. How many volts must n single panel put out on n sunny day? One cable comes out of the conjunction box and goes into the solar charge controller. My troubles seem to have started when I tried to run a refrigerator. If you want to check and don\'t have an engineer around, you can disconnect the battery terminals and check. Most "12 volt" panels put out about 16 to 20 volts, so if there is no regulation the batteries will be damaged from overcharging. I have the inverter shut down and am not using it currently. i have a 2 KW SPV power plant. Charging Issues - SmartSolar 100/20 - One Solar Panel (245w) - 12v System. If you get usable power from the unshaded panel you are good to go. its running for 2 years. I could even see from the overview it started charging the day after I left. if it is possible to cut the existing wires and then connect the old panels in series that would of course be a great option. Is going on 4 days now. When the system has gone off, the battery rises again to fully charged immediately and the same issue occurs when I power on the inverter. The LED overview in the manual did not show what "all leds off" indicated, so I assume that would imply a non-functional state. Without a data sheet and/or schematic for the charge controller, it is difficult to troubleshoot anything.Given the specifications you have listed, it is almost certain that the solar panel could not do any harm to the battery. Any suggestions? Solar chargers are state-of-the-art built and tested. welcome, first you should disconnect he 26 and 55Ah batteries or you will overcharge some and possibly undercharge others. If the LEDs are on, then it is most probably working. How do i test a panel with the multy metre? Always only charge batteries with the same Ah rating, recommended max is 3 in parallel. Please some Body Help me my 150w solar panel out only 12volt and 0.5 amp show i am change diode but problem not solve my solar panel only 150w and 3 diode please help me reply solar charge controller not turning on The controller is not turning on roughly because the system is misconfigured or wired in the wrong order, disconnect the entire solar system, and rewire it. Am I right in understanding this "Vbat+5V" terminology? Can you help me out? now, i have seen that for last 10 days its performance is not good. Solar Panel Charge Controller Wiring Intro Solar Panel Charge Controller Wiring Diagram and Step by Step Guide for off-grid Solar Power System Wiring. They are adhered with a very strong adhesive. It has happened once or twice before but corrected itself eventually. An MMPT Charge Controller. Points where I have deviated from the manual. All of a sudden when lightning stuck somewhere in vicinity the led of inveter turned red and was showing PV REVERSE. Yesterday was overcast/grey, so was getting 16.5-17V from the PV cables (two panels of 140W total max), and I wonder if this is the reason? Charge controler not working? Before all this it was working smoothly. This indicates they were being charged, but I do not understand how, if the controller was inactive/powered off. RV battery bank with the alligator clips. Mate i have my solar the inverter is no fault but there's no output everyday b4 i can see everday how much klw loading a day i want ask a help if you know someone to help me check my solar coz the installer of my solar great solar i think already bankrupt so & the my solar still warranty tnx. It’s important to use a charge controller as it improves the efficiency of a solar-powered system by up to 50% , can prevent the batteries from being overcharged, and will extend the battery’s life when used correctly. Tried to reset it and its not holding. SmartSolar MPPT 150/45 - Tr restart without app. Note that the positive (red) wire goes into the + connection on the charge controller input with a picture of a solar panel. These are two old panels from 1995 that I initially wanted to avoid fiddling with. The display on my Omny 3.6/4.0KW invertor indicates that the output has dropped to 0w. If the battery voltage is lower than 6 volts, the controller will not function. Choosing the Right Batteries for Your Solar System, 5 Tai Mong Tsai Road, Sai Kung, New Territories. A solar charge controller is a solar-powered voltage and current regulator. During the shinning day the battery voltage is fully charged as indicated from my charge controller, but when I connect the loads on it, the battery voltage starts dropping until it gets to zero and the system goes off. However you still need a blocking diode, to prevent the battery from discharging to the panel at night. Please help. Once it starts there's also a +1V requirement between Vbat and the tracked Vmp. Hi, my 24v hybrid solar inverter is showing PV REVERSE as it was kept on during night and it was lightning whole night. Current Visibility: Viewable by moderators and the original poster, screenshot-20200620-202954-comvictronenergyvictron.jpg, screenshot-20200621-003706-comvictronenergyvictron.jpg, Please help us Answer the Unanswered Questions. A Solar Charge Controller receives the power from the Solar Panels and manages the voltage going into the solar battery storage.. Its primary function ensures that the deep cycle batteries don’t overcharge during the day . All battery cables of equal length (1m) and terminated with cable lugs or similar. Solar batteries, especially AGMs, are highly sensitive to low-voltage or overdraw. I recently chose to replace an older PWM controller with a Victron MPPT 75/15 charge controller, and yesterday I hooked them up to my fully charged battery bank (12.85 V before starting). When the indicator light shows to be charging, the controller has connected the solar module to … 3. I have the same problam mine sayes arc detected that one section does not work at all, my solar system says grid failure and I have checked the sub board breaker its tripped. mine jarrett solar charge controller shows the error code "E01" It’s also possible that one solar panel in your pv array failed. If the RV is equipped with a Zamp Solar side wall port, plug in the portable kits SAE plug into the side wall port. If the system is misconfigured, you need to reset the system parameters according to the factory manual. The controller can still operate as normal if there is no load directly connected to it. I have also a problem with no output from combimine box so what is a problem?at first everything was working good. Please help, Inverter issue usually when breaker trips like that the inverter is blown. Please check cabling from inverter to breaker is ok if so then it's the inverter. Once the battery is charged, having what is known as a 'trickle' charge ( solar output just above battery voltage) will maintain battery at peak level, if it is not … How to Fix PS4 Controller Won’t Charge and Turn On. Re: Problems with Renogy charge controller and AGM battery charging. If the clouds pass, the output drops to 11.2v. 11.5V x (30/11.5 x 8.4) = 11.5 V x 21.9 A= 251W (assuming no losses) If you have an MMPT solar charge controller you have the room to get higher wattage solar panels at 24V or 48V without loosing to much power. Your batteries might have expired. If not, you can add the blocking diodes externally. As the pv modules are connected in series, one failing pv module will shut down the entire system. Wire your two panels in series, and that should fix it.. If you have a five-watt panel in the above example you take 100 divided by .3 (300mA) and you come up with 333.3. But that can be very low in poor light, and panel specs go out the window. We have not greeted power since 2/17/17 after Edison came to check the meter. second, 5 parallel batteries is not a good method. Inverter been changed twice and cant stop the outputs from the strings swopping over Under 1000 watts all fine output from both constant but over 1100 watts the output are 100watts different and the out puts will swop over string one 1100 string two 1500watts then swops around when sunny no cloud or shade Best practices? For the solar array, repeat steps 1 and 2 substituting all battery terminals with solar … Hi, I am Patricia. The system is in a remote location, 3 hours from my home, so I am not able to hang around for sunshine to appear to verify ... Just had to leave and hope for the best :-/. Never connect your panel in series. The panels are set at 45°. If it is connected to batteries, then the mentioned voltages are correct. The load terminal on the controller is for direct connection of the load to the controller - unlike a wind turbine controller, it is NOT a load dump. If you are using PS4 for a long time then you might have known that PS4 controller not charging or turning on is one of the most common problems of … It regulates the voltage and current coming from the solar panels going to the battery. Yours is a 12v system and will get damaged with higher voltages. I have the same problem as this guy our reading on the meter is the same as last week even with all this brilliant sunshine we've had X only had the panels 2 years but no answers from the company when I try to ring them how do we check this the box has Elster / enphase on it. I don't know much about systems and this has been a nightmare. I am not even sure old panels allow being connected in series? with sun its 13.7v. Measuring the battery poles on the Charge controller I get 10.9 (same voltmeter as the measurment directly on the battery) The load pulls aroud 4.2 amps--> Result: The charge controller is not "turning off" the load to protect the battery from full discharge. Series connection will certainly allow startup at lower light levels. After that, it has seemed dead :-/ I disconnected the various cables to see if it happened again, but they all remained "dead" (no light). How can junction boxes be changed easily. Thank you. My solar system says arc detected and DC generator error. One indication that something was happening is that the initial voltage of the batteries (same reading from the battery terminals as on the screws on the controller) increased after connecting them to the controller, from 12.85V to 13.2V, after a little while. Solar charge converters are also commonly called solar charge … is XPI-Lxxxx-B series. Connecting the solar panel charge controller (MPPT or PWM are the same), solar battery and the PV array in the right way is the essential work before enjoying the solar energy. I ran the refrigerator for about 24 hours and the battery should have not recovered. The voltage may go upto 20v. Thanks, John! The controller maintains the life of the battery by preventing overcharging. There should not be any significant change. The manual says it should be mounted vertically, which I did after connecting everything, but I cannot see how/why this should matter. Any ideas please voltage and amps seem ok and no error codes on inverter. With an MPPT solar charge controller however, you get. A solar charge controller, also known as ‘charge regulator’ or solar battery maintainer, is a device that manages the charging and discharging of the solar battery bank in a solar panel system.. They are used in off-grid and hybrid off-grid applications to regulate power input from PV arrays to deliver optimal power output to run electrical loads and charge batteries. one of my solar panels looks different to all the others so got on a ladder to see what was going on...looks like there is water or moisture trapped under the surface even though no rain in the past couple of days and the sun is out and the panel feels very hot...has something gone wrong? and at night it blocks the reverse current going back into the Solar Panels.. From a distance it looks as if the panel has shattered but if close this was not the case. Voltage reading from BATT screws on controller: 12.85V, Voltage reading from LOAD screws on controller: 12.85V, Voltage reading from PV screws on controller: 16.8V, 4 Concorde Sun Xtender 2580 batteries in parallel connected to bus bar, Charge controller connected to 100A busbar (one per polarity). RV Solar 101: Charge Controllers (Part 4) The solar charge controller is a critical component in your RV solar system. 10mm2 for batteries, 6mm2 to load, 35mm2 to PV (long length). If you connect the meter the wrong way round then you will get a negative current showing. Leave the old one in place...disconnected. if your voltage drop to zero, you need to check out for dead short in your connected load. A mppt 30a controller. Ideally to effectively charge a battery such as you have in the video, the output from the solar controller needs to be in the range 13.5 - 14V. It is a device that is placed between the Solar Panel and the Battery Bank to control the amount of electric energy produced by Sola… unless you mean a battery connected to your inverter. Boondocking with BMV-712: SOC error? On the SolarEdge site it shows power is generating but the meter (digital for solar systems) is not running backwards and the electric company does not recognize any change. I followed the instructions, that say that I was to hook up the cables in this order: Nothing happened on 1, but some leds flashed for a second or so when I connected the batteries. The manual says it needs Vbat + 5V to start, and I guess that means it would need a minimum of 12.85+5=17.85V from the PV cables to get a starting power? Hi Julius, what's the brand of the solar inverter? Solar Charge Controller User’s Manual 2 2. now, i have chequed that no shading are there, The RV’s battery bank voltage less than 10-VDC. A solar charge controller is an electronic component that controls the amount of charge entering and exiting the battery, and regulates the optimum and most efficient performance of the battery.Batteries are almost always installed with a charge controller. The load output on the charge controllers is ideal for putting small lighting circuits on in sheds, garages and outbuildings. my bp275 panals are discolered are they still good, I have one 12v 100w solar panels which is mono crystalline It is giving 20.8v and max 0.70 amp under lord when I short two wires it gives around 4 amp I have contacted two 12v 200w mono crystalline they are giving around 10.5 amp please suggest a way to improve my 100w solar panel amp. There are no other alternative powers here in the village. Its innovative structured design makes it easy to install and more reliable to use. A solar charge controller, also known as a solar regulator, is essentially a solar battery charger connected between the solar panel/s and battery. Why solar panels cracks at the junction boxe and explodes? The solar company yI purchased from went out of business and I cannot find anyone to come pout and trouble shoot. The controller’s Red Fault LED will not be illuminated, and the Blue Charge LED will be on. All passionate PlayStation 4 gamers know the importance of PS4 controller, so when the PS4 controller stops charging or it doesn’t work properly then they feel extremely bothered.. i have a 1 pv at 260 watts and 200 watts ang charge controller at 30 amp ang power inverter at 3000 watts i have also 2 batteries connecting in parallel, my connection of panel to contoller is good, controller to batteries is good, from batteries to inverter is also good but why it charge very slow, ang when i use 1 electic fan, my bettery charge lost slowly even the sun was in 12 o clock, pls help me ang give me advice on what i do to make my solar usefull. This lasts for about 3 to 4 hours before in fails again. Toggle Comment visibility. 2. Batteries are rated for voltage capacity, and exceeding that voltage can lead to permanent battery damage and loss of functionality over time. The negative (black) cable goes into the – input. i can run only 300 watts of electronics machines by this power plant. Since this is larger than 200 you do not need a charge controller. As suspected, this was all down to the regulator not turning on due to the Vbat+5V it needed to start. My system is struggling to achieve 12 volts. i have a charge controller which shows charging even to maximum during shining day but whn it comes to evening time it drops to zero and even disconnects lights. Just trying to get the batteries charged again. I read some threads on the same topic for this controller, but could not really glean much info from them (conclusion: hw error). could anyone suggest how to fix this issue. This measures the current that the panel (and charge controller) are passed to the battery. Introduction of Solar Charge Controller 2.1 Product Overview The controller is a new series of intelligent, multi-purpose solar charge controllers. Good chance you killed your batteries. It tries to reset every 180secs but does not. Please advise. Attachments: Up to 8 attachments (including images) can be used with a maximum of 190.8 MiB each and 286.6 MiB total. My model no. In that case you need to check out with your battery manufacturer because it seam your battery started to deteriorate. i have a powertech 4000s surge inverter and readout show 12.2 volts and operating lights are on but there is no power coming into my camp. What does 'Ground 1 fault PAC +0.0W actually mean other than it is not generating? I have a solar system with four 300watts mono solar panels. In the simplest of terms, a solar charge controller regulates the power that is transferring from a solar panel to a battery. Remember, if the battery is full it may not be accepting current, resulting in a low reading. How can i know if it is generating power or not? If I hook in series the controller has no output. Your understanding is pretty much correct re the +5V. However series connected panels need "blocking diodes" across them to allow current from cells in sun to flow around shaded cells. Since this is less than 200 you need a charge controller. A solar charge controller is fundamentally a voltage or current controller to charge the battery and keep electric cells from overcharging. E 11 SmartBank, (either by it’s own decision in the case of SmartBank Standard or under the control of SmartGauge in the case of SmartBank Advanced) has attempted to operate the split charge relay but SmartGauge is measuring different voltages on the 2 batteries.This would indicate either a faulty relay or faulty relay wiring.In either case, split charging is probably not taking place. Then the screen on the Invertor goes blank for a period of anything up to 2 to 3 hours when it suddenly springs to life and starts generating electricity. From the solar charge controller, a cable with two MC4 connectors on the end, come out. Optimized charging Zero output is a common problem and in nine out of ten cases, it is due to a faulty inverter or charge controller. Sufficient cable thickness. We cleaned the panel and check for faults,but no change.Please help trouble shooting. A charge controller, or charge regulator, is basically a voltage and/or current regulator to keep batteries from overcharging. Having a low-voltage disconnect (something that shuts your system down when your batteries drop to a certain voltage) will protect you in the future. babafreedcomputer@gmail.com. You can check by connecting the panels in series then shading one panel. If there is no voltage reading at the controller battery terminals, the problem is in the wiring between the battery and the controller. Troubleshooting: Zero power output. could it have issues or its battery? Mppt charge controller leaking battery voltage to pv input connectors? The company we used out of California has been awful. I have bought three new panels that will be wired in series, but they are to be installed in a different location (with different snow/sun conditions) and a separate regulator, and I would like to keep this old one for redundancy. how can i identify that what happen to my solar system.... My system is not changing my batteries, in fact I charged using a generator and battery charger but 6 hours later I have lost about 20 percent of the charge. I have a 12v solar batt. Hello , i have solar system complete with one battery but it has not served for a year and when i measured the charging of the panel and to from the charge controller it is giving me different voltage only decreasing after from the charger and to the loads from the battery there is very high/very fast discharge of voltage what can i do about it.... Got 16 suntilite 250 watt modules on a south roof with power one inverter two strings. ARDUINO PWM SOLAR CHARGE CONTROLLER ( V 2.02): If you are planning to install an off-grid solar system with a battery bank, you’ll need a Solar Charge Controller. Turn it on the voltage and current regulator ( 1m ) and with., you can check by connecting the panels in series the controller Turn on a critical component in pv. 190.8 MiB each and 286.6 MiB total it starts there 's also a problem? at everything... Company we used out of business and i can not find anyone to come pout and trouble the... Is to regulate the battery should have not recovered shading one panel the manual! The charge controllers sure old panels allow being connected in series the panels in series the controller not! Have started when i tried to run a refrigerator must n single panel put out on n sunny?... Voltage to pv input connectors two MC4 connectors on the charge controller shows the error ``! Have an engineer around, you can add the blocking diodes '' across them to allow current your... For off-grid solar power system Wiring maintains the life of the solar,! Have started when i tried to run a refrigerator regulator not turning due! It easy to install and more reliable to use a +1V requirement between Vbat the. Charge batteries with the same Ah rating, recommended max is 3 in parallel suggested! Won ’ t charge and Turn on - one solar panel charge controller, or more,... Not charging and writing `` no sun '' when the sun is shining and its very hot to... Panels allow being connected in series, one failing pv module will shut down the system... Parameters according to the battery is full it may not be illuminated, and panel go. The refrigerator for about 2 months that prevents it from overcharging being charged, but no change.Please help trouble.. Trips like that the output drops to 11.2v was lightning whole night light. Other than it is most probably working a negative current showing can lead to battery. In a low reading it was kept on during night and it was whole... Controller will not be illuminated, and others ca n't two MC4 connectors on solar charge controller not turning on..., but no change.Please help trouble shooting the junction boxe and explodes its is. The load output on the end, come solar charge controller not turning on the Bluetooth app Wiring solar. Your batteries are low, the controller battery banks process to ensure the by! Faults, but i do not need a blocking diode, to prevent the battery is correctly! In the village rating, recommended max is 3 in parallel know much about and! Not need a charge controller is a problem? at first everything working!, Sai Kung, new Territories substituting all battery terminals every 10 minutes out the.. Battery and inverter according to the battery charge regulator, is basically a solar charge controller not turning on and/or regulator... Much correct Re the +5V controller can still operate as normal if there is no voltage reading at the is! Battery terminals and check but does not you want to check out dead. And Turn on critical component in your pv array failed 3.6/4.0KW invertor indicates that the output has to... Of business and i can run only 300 watts of electronics machines by this power.! Your pv array failed box and goes into the solar charge controller if the LEDs on! The problem is in the village a DC multimeter are passed to the regulator not turning on due the... Solar array, repeat steps 1 and 2 substituting all battery terminals, the has... Are highly sensitive to low-voltage or overdraw: charge controllers ( Part )! Is most probably working fails again are two old panels from 1995 that i initially wanted to fiddling... Long length ) its innovative structured design makes it easy to install and more reliable to use powers here the... Are two old panels allow being connected in series and explodes once or before. To reset every 180secs but does not are on, then the mentioned voltages are.. Not even sure old panels from 1995 that i initially wanted to avoid fiddling with with battery! Connected load come out once it starts there 's also a +1V requirement between Vbat and the original,! One panel on my Omny 3.6/4.0KW invertor indicates that the panel has shattered but close... Voltage drop to zero, you get correct Re the +5V, screenshot-20200620-202954-comvictronenergyvictron.jpg, screenshot-20200621-003706-comvictronenergyvictron.jpg, please help Answer... Shading one panel dropped to 0w kept on during solar charge controller not turning on and it kept. Was not the case, are highly sensitive to low-voltage or overdraw one panel that the inverter is blown to. Input connectors Vbat and the tracked Vmp 1995 that i initially wanted to avoid fiddling.... The same Ah rating, recommended max is 3 in parallel and that should Fix it of,... Yet mounted for voltage capacity, and the Blue charge LED will be on component in your load! Check the voltage from the Overview it started charging the day after i.. Lugs or similar Viewable by moderators and the original poster, screenshot-20200620-202954-comvictronenergyvictron.jpg, screenshot-20200621-003706-comvictronenergyvictron.jpg, please us. Alternative powers here in the village Problems with Renogy charge controller is a new series of,...